Ozone aging test chamber Usage
|
|
Ozone aging test chamber for aging cracking of rubber products.
Box structure
Box using CNC machining, nice shape, no reaction door handle, easy to operate.
Ozone aging test box liner made of imported high grade stainless steel plate, cabinet outside the gall A3 steel spray, increasing the appearance of texture and cleanliness.
Heating fever style heating, fast heating, temperature distribution.
Built-in 360-degree rotating sample holder.
|

|
Ozone aging test control systems
|
|
Ozone aging test imported ozone concentration control analyzer with standard signal output and sampling.
Silent discharge ozone generator (with low noise, high purity)
Imported digital temperature controller touch buttons, PID microprocessor temperature controller SSR.
|

|
Ozone aging test standard
|
|
GB/T7762-2003 GB/T2951.21-2008
|

|
Ozone aging test specifications and technical parameters
|
|
Model(MM)
|
QJ-100
|
QJ-225
|
QJ-500
|
QJ-010
|
Studio Size
|
400*450*550
|
500*600*750
|
700*800*900
|
1000*1000*1000
|
Dimensions
|
860*870*1730
|
940*1050*1970
|
1353*1220*2120
|
1460*1420*2050
|
Power
|
3.0(KW)
|
4.5(KW)
|
6.0(KW)
|
6.5(KW)
|
Performance indicators
|
Temperature Range
|
0℃~70℃
|
Humidity Range
|
30~65%R.H
|
Ozone concentration
|
10~1000pphm
|
Temperature fluctuation
|
±0.5℃
|
Control System
|
Test device
|
Dynamic and static
|
Rack speed
|
360 degree rotating sample holder (1 rpm per minute)
|
Gas flow
|
10~20mm/s
|
Temperature Controller
|
Imported LED digital PID + SSR microcomputer integrated controller (optional touchscreen)
|
Time controller
|
Hours, minutes, seconds, time controller
|
Ozone concentration analysis
|
Analysis regulator inlet concentration 4 ~ 20mA output,
|
Ozone generator
|
Silent discharge type / UV absorption
|
Security
|
Leakage, short circuit, over temperature, motor overheating, over-current protection
|
|
|